Version 4 SHEET 1 896 808 WIRE 16 0 -128 0 WIRE 288 0 96 0 WIRE 624 0 288 0 WIRE -128 112 -128 0 WIRE 288 128 288 0 WIRE 624 128 624 0 WIRE -128 272 -128 192 WIRE 288 272 288 192 WIRE 288 272 -128 272 WIRE 624 272 624 208 WIRE 624 272 288 272 WIRE -128 288 -128 272 FLAG -128 0 in FLAG 288 0 out FLAG -128 288 0 SYMBOL cap 272 128 R0 SYMATTR InstName C1 SYMATTR Value 2704 SYMBOL res 608 112 R0 SYMATTR InstName R1 SYMATTR Value 1.333 SYMBOL res 112 -16 R90 WINDOW 0 0 56 VBottom 2 WINDOW 3 32 56 VTop 2 SYMATTR InstName R2 SYMATTR Value 0.2 SYMBOL current -128 192 R180 WINDOW 0 24 80 Left 2 WINDOW 3 24 0 Left 2 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName I1 SYMATTR Value PWL(0 0 1 13 20000 13 20001 0) TEXT -128 344 Left 2 ;C1=Aluminiumklotz 0.15m*0.15m*0.05m=0.001125m³\nspezifische Wärmespeicherkapazität c=890Ws/K*kg\nWärmewiderstand Lambda=210W/K*m\nOberfläche=(0.15m*0.15m)*2+(0.15m*0.05m)*4=0.075m²\nDichte Aluminium rho=2700kg/m³, Masse Kupferklotz=3.038kg\nC1=c*m=890Ws/K*kg * 3.038kg=2704Ws/K TEXT -128 568 Left 2 ;R1=Kühlung des Kupferklotz durch Wärmeabstrahlung an die Umgebung.\nWärmeabstrahlungskoeffizient Metall and ruhende Luft=10W/K*m*m.\nR1=1 / (10W/K*m²) * 0.075m² = 1.333 K/W TEXT -128 704 Left 2 ;R2=Wärmeübergangswiderstand der Heizung auf den Kupferklotz.\nGeschätzt auf 0.2K/W. TEXT -104 248 Left 2 !.tran 40000 TEXT -128 792 Left 2 ;I1=konstante Heizleistung von 13 Watt